logo

Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors

1
MOQ
USD
가격
Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors
풍모 갤러리 제품 설명 따옴표를 요구하십시오
풍모
제품 사양
제품 이름 :: 의학 배터리
모델:: 989803152881
셀 유형 :: 리튬 이온 배터리
상태:: 새로운
전압:: 14.8V
용량:: 6.6Ah
에너지:: 97.68Wh
경향 :: 8.0A
스토리지 수명 :: 2.5년
사이클 수명 :: ≥600배
강조하다:

14.8V Medical Battery

,

97.68Wh Lithium-ion Battery

,

Compatible with invivo 9065/9067 Monitors Medical Battery

기본 정보
결제 및 배송 조건
포장 세부 사항: 상자 패키지
지불 조건: T/T, Western Union, PayPal
제품 설명
Philips invivo 9065 989803152881 9067 Brand New Original Battery
The Philips invivo 9065/9067 Monitor Battery (REF: 989803152881) is compatible with multiple monitors including the invivo 9065 Critical Care Multi-Parameter Monitor and invivo 9067 High-End Neurocritical Care Monitor. This 14.8V, 6.6Ah battery delivers stable, long-lasting power for continuous patient monitoring in critical care environments.
Key Features
  • Long-Term Stable Power Supply: Provides 4.5-5.5 hours of continuous operation with dual battery support extending to 9-11 hours, ideal for complex monitoring and patient transport scenarios.
  • Intelligent Status Monitoring: Real-time battery life and charging progress display on monitor with low battery alerts.
  • Hot-Swap Design: Enables battery replacement without interrupting critical monitoring, essential for neurological and cardiac procedures.
Technical Specifications
Product Name Philips Battery
REF 989803174881
PN 989803152881
Battery Type Lithium-ion battery
Voltage 14.8V
Capacity 6.6Ah
Energy 97.68Wh
Condition New original
Current 8.0A
Interface Type Waterproof smart interface (with metal lock)
Storage Life 2.5 years
Cycle Life ≥600 times
Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors 0 Philips invivo 9065/9067 Medical Battery 14.8V 97.68Wh Lithium-ion Battery Compatible with Critical Care Monitors 1
Frequently Asked Questions
Q: With high-frequency EEG sampling enabled, battery life reduces to 3.5 hours instead of rated 5 hours. Is this normal?
A: Yes, this is expected due to increased power consumption from EEG sampling (approximately 3.2W). Additional monitoring functions further reduce operational time.
Q: My new battery shows "Battery Not Authenticated" when installed. What should I do?
A: First verify the security code on the battery label. If authentic, clean the metal contacts with alcohol and ensure proper connector engagement.
Q: After 4 months storage, the battery won't power the monitor. How can I activate it?
A: Charge for 2 hours to wake the lithium battery from dormancy, then calibrate and fully recharge before normal use.